Sign In
Upload
Manuals
Brands
ABB Manuals
Inverter
REACT-3.6-TL
ABB REACT-3.6-TL Manuals
Manuals and User Guides for ABB REACT-3.6-TL. We have
2
ABB REACT-3.6-TL manuals available for free PDF download: Product Manual, Application Note
ABB REACT-3.6-TL Product Manual (174 pages)
From 3.6 to 4.6 kW, solar inverters
Brand:
ABB
| Category:
Inverter
| Size: 16.68 MB
Table of Contents
Ntroduction and General Information
4
Warranty and Supply Conditions
4
Not Included in the Supply
4
Table of Contents
5
Reference Number Index
9
Graphical Representation of References
10
React-3.6/4.6-Tl
10
React-Uno-3.6/4.6-Tl
11
React-Batt-Ap1
12
React-Mtr-1Ph
13
React-Mtr-3Ph
13
Scope and Target Audience
14
Purpose and Document Structure
14
List of Appendix Documents
14
Operator and Maintenance Personnel Skills/Prerequisites
14
Symbols and Signs
15
Field of Use, General Conditions
17
Intended or Allowed Use
17
Limits in Field of Use
17
Improper or Disallowed Use
18
Haracteristics
19
General Conditions
19
Models and Range of Equipment
20
Identification of the Equipment and Manufacturer
21
Characteristics and Technical Data
22
Tightening Torques
25
Overall Dimensions REACT-3.6/4.6-TL
26
Overall Dimensions REACT-MTR-1PH
27
Overall Dimensions REACT-MTR-3PH
27
Dimensions Main Bracket REACT-3.6/4.6-TL
28
Dimensions Additional Bracket (REACT-BATT-AP1)
29
Efficiency Curves
30
Power Limitation (Power Derating)
31
Power Reduction Due to Environmental Conditions
32
Power Reduction Due to the Altitude of the Installation
33
Output Power Reduction Due to the Input Voltage
34
Input Power Reduction Due to the Input Voltage
35
Characteristics of a Photovoltaic Generator
36
Strings and Arrays
36
Description of the REACT System
37
Notes on the Sizing of the System
37
Operating Diagram
38
Operating Stages of the System
39
Functionality and Components of the Equipment
40
Topographic Diagram of the Equipment
43
Safety Devices
44
Anti-Islanding
44
Ground Fault of the Photovoltaic Panels
44
STOP" Button
44
REACT-BATT-AP1 State of Health (SOH)
44
Other Safeguards
44
Afety and Accident Prevention
45
Safety Information and Instructions
45
Hazardous Areas and Operations
46
Environmental Conditions and Risks
46
Signs and Labels
46
Thermal and Electrical Hazard
47
Clothing and Protection of Personnel
47
Safety Precautions Relating to REACT-BATT-AP1
48
Residual Risks
50
Table of Residual Risks
50
Ifting and Transport
51
General Conditions
51
Storage of Equipment
52
Special Rules for Storage of REACT-BATT
52
Lifting
53
Equipment Weight
53
Transport of the Equipment
54
Transport of the REACT-BATT-AP1
54
Overview of the "Ancillary Rule" and the "1000 Units Rule
54
Unpacking and Checking
56
List of Components Supplied
56
Nstallation
58
General Conditions
58
Environmental Checks
59
Installation Position
61
Wall Installation of the REACT System
62
Wall Installation of the REACT-UNO Alone
66
Connection of the Energy Meter (REACT-MTR)
70
Connection of the REACT-MTR-1PH (Mono-Phase)
70
Communication and Control Signal Terminal Block
71
Connection and Configuration of the REACT-MTR-3PH
72
(Three-Phase)
72
Preliminary Operations for Connection of the PV Generator
74
Checking the Correct Polarity of the Strings
74
Checking of Leakage to Ground of the Photovoltaic Generator
74
Selection of Differential Protection Downstream of the Inverter
74
Distribution Grid Output Connection (AC Side)
76
Characteristics and Sizing of the Line Cable
76
Load Protection Switch (AC Disconnect Switch)
77
Connection to the AC Side Terminal Block
77
Back-Up Output Connection (AC)
78
Characteristics and Sizing of the Cable for Back-Up Output
79
Load Protection Switch (AC Disconnect Switch) for Back-Up Output
79
Connection to Back-Up AC Output Terminal Block
80
Configuration of Independent or Parallel Input Channels
81
Channel Configuration Examples
82
Independent Channel Configuration (Default Configuration)
83
Configuration of Parallel-Connected Channels
83
Input Connection to PV Generator (DC Side)
84
Installation Procedure for Quick-Fit Connectors
86
Communication and Control Signal Connections
90
Description of Communication and Control Signal Terminal Blocks
91
External Backup Command Connection
92
Remote Control Connection
92
Output Connection
93
Connection of RS485 M-B (Modbus) Serial Communication Line
93
Connection of RS485 PC Serial Communication Line
95
Connection of RS485 METER Serial Communication Line
97
Configurable Relay Connection (ALARM)
99
Connection to Load Management System (Load Manager Box)
100
Nstruments
101
General Conditions
101
Display, Keyboard and Status LED
102
Description of Symbols and Display Fields
102
Description of the Keyboard and Status Leds
106
Peration
107
General Conditions
107
Monitoring and Data Transmission
108
User Interface
108
Measurement Tolerance
108
Commissioning
109
Updating the Firmware from an SD Card
117
LED Behaviour
118
Specifications on the Behaviour of the Leds
119
Red GFI LED
119
Description of the Menus
120
General Information
120
Menu Structure
122
System Menu
123
Inverter Menu
127
Display Menu
139
Meter Menu
140
Battery Menu
142
Load Manager Menu
146
Wi-Fi Logger Menu
146
REACT System Switch-Off
147
Aintenance
148
General Conditions
148
Routine Maintenance
149
Troubleshooting
149
Alarm Messages
149
Power Limitation Messages
162
Procedure for Dismantling of the REACT System
164
Registration on “Registration” Website and Calculation of Second-Level Password (Service
165
Registration on "Registration" Website and Calculation of Second-Level Password (Service Menu)
165
Resetting the Time Remaining to Change the Grid Standard
168
Verification of Ground Leakage
169
Behaviour of a System Without Leakage
169
Behaviour of a System with Leakage
170
Measuring the Insulation Resistance of Photovoltaic Generator
171
Storage and Dismantling
172
Storage of the Equipment or Prolonged Stop
172
Dismantling, Decommissioning and Disposal
172
Further Information
173
Contact Us
174
Advertisement
ABB REACT-3.6-TL Application Note (19 pages)
BACKUP OUTPUT USE, Operation and Configuration
Brand:
ABB
| Category:
Inverter
| Size: 1.6 MB
Table of Contents
Table of Contents
2
1 Scope and Field of Application
3
2 Operation Principle
3
3 General Recommendations
4
4 Specifications
4
5 Operation Modes
6
Selecting the Mode: Overview
7
Operating Conditions
7
Mode Configuration
15
Control/Signal from External Logic
16
6 Priority Loads Relay
17
Advertisement
Related Products
ABB REACT 2 Series
ABB REACT2-UNO-3.6-TL
ABB REACT2-UNO-5.0-TL
ABB REACT-4.6-TL
ABB REA 105
ABB REA 10 Series
ABB REA 101
ABB REA 103
ABB REA 107
ABB REC601
ABB Categories
Industrial Equipment
Controller
Measuring Instruments
Battery Charger
DC Drives
More ABB Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL