Parameters Setting - Smartgen HGM400N Series User Manual

Genset controller
Hide thumbs Also See for HGM400N Series:
Table of Contents

Advertisement

8

PARAMETERS SETTING

Start the controller, then press
1.
Set Parameters
2.
Information
3.
Language
4.
Event Log
5.
Maintenance Setting
a) Parameters Setting
"0318" can set all items in 7.1 during inputting password. When default password has been
changed, it needs to input the same password with controller for parameter setting via PC software.
If more parameter items need to be set or password is forgotten, such as voltage and current
calibration, please contact with the factory.
Note:
1)
HGM410N, there are not items 1-5 in 7.1; programmable output 1-4 have no digital outputs about
mains.
2)
Please modify the parameters in standby mode (crank conditions, auxiliary input and output
configuration, multi delays, etc.) otherwise shutdown alarm or other abnormal conditions may
appear.
3)
The over-voltage threshold must be greater than the under-voltage threshold; otherwise
over-voltage and under-voltage will occur at the same time.
4)
The over-speed threshold must be greater than under-speed threshold, otherwise over speed and
under speed will occur at the same time.
5)
Set frequency value (after crank disconnect) as low as possible, in order to disconnect starter
quickly.
6)
Programmable input 1-4 cannot be set as the same items, otherwise it cannot realize correct
function; programmable output 1-5 can be set as the same item.
7)
Digital input 3 can be configured as Fuel Level Sensor. Digital input 4 can be configured as
Temperature Sensor, Oil Pressure Sensor and Water Level Sensor. Digital input and sensor need
to be picked one: if input is chosen, the corresponding digital input parameter is active and the
sensor parameter inactive but saved; otherwise if sensor is chosen, the corresponding sensor
parameter is active and the digital input parameter is inactive but saved.
If need to shut down after cooling, please set any input as " stop after cooling ", then connect this
8)
input to ground; or set high temperature stop action as "cooling stop"
b) Information
LCD will display some information of controller, such as software version, hardware version, issue date.
Note: Pressing
will display the status of digital inputs and outputs.
c) LCD contract
Press
and
(or
d) Language
User may select display language as Chinese, English, Spanish, Russian, Turkey and French.
e) Event Log
Users can check event log (max. 99) on this interface including start/stop info and shutdown alarms.
f) Maintenance Setting
The default password (when enter maintenance setting) is 0 (it needs to contact sales or after sale
personnel to change the password). It'll refresh maintenance time after entered maintenance setting.
Remark: It will enter into the next maintenance period after refreshing the time in the maintenance
HGM400N Series Genset Controller
to enter into the parameters setting menu as below:
and
) can adjust LCD contract. Adjustment range is 0-7.
2017-04-21
HGM400N Series Genset Controller User Manual
Version 1.2
Page 29 of 36