Connections - Smartgen HGM400N Series User Manual

Genset controller
Hide thumbs Also See for HGM400N Series:
Table of Contents

Advertisement

6

CONNECTIONS

Compared with HGM420N, HGM410N has no Mains AC Voltage input terminals. The rear panel of
HGM420N is as below.
Description of terminal connections:
Pin
Function
1
B-
2
B+
3
Aux. Output 1
4
Crank
5
Aux. Output 2
6
Aux. Output 3
7
Digital Input 1
8
Digital Input 2
9
Digital Input 3
10
Digital Input 4
HGM400N Series Genset Controller
HGM400N Series Genset Controller User Manual
Cable Size
2
2.5mm
Connected with negative of starter battery.
DC power supply. Connected with positive of starter
2
2.5mm
battery. If wire length is over 30m, better to double
wires in parallel. Max. 20A fuse is recommended.
B+ is supplied by 2 point, rated
2
1.5mm
5A.
Crank Relay Output; B+ is
2
1.5mm
supplied by 2 point, rated 5A.
Connect to starter coil.
B+ is supplied by 2 point, rated
2
1.5mm
5A.
B+ is supplied by 2 point, rated
2
1.5mm
5A.
2
1.0mm
Ground connected is active (B-)
2
1.0mm
Ground connected is active (B-)
Ground connected is active (B-);
2
1.0mm
Can be used as Level Sensor.
Ground connected is active (B-);
2
1.0mm
Can be used as Config. Sensor.
2017-04-21
Description
See
Performance
and
Characteristics
See
Version 1.2
Page 16 of 36
7.3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hgm420nHgm410n

Table of Contents