Default Jumper and Switch Settings

Figure 2-1
shows the ZCU104 board jumper header and DIP switch locations. Each
numbered component shown in the figure is keyed to
settings) or
Table 2-3
schematic page numbers.

Jumpers

Table 2-2: Default Jumper Settings
Number
Ref. Des.
33
J85
34
J12
34
J13
35
J20
35
J21
35
J22
ZCU104 Board User Guide
UG1267 (v1.1) October 9, 2018
(for default switch settings). Both tables reference the respective
Function
POR_OVERRIDE
• 1-2: Enable
• 2-3: Disable
SYSMON I2C address
• Open: SYSMON_VP_R floating
• 1-2: SYSMON_VP_P pulled down
SYSMON I2C address
• Open: SYSMON_VN_R floating
• 1-2: SYSMON_VP_N pulled down
Reset sequencer PS_POR_B
• Open: Sequencer does not control
PS_POR_B
• 1-2: Sequencer can control PS_POR_B
Reset sequencer PS_SRST_B
• Open: Sequencer does not control
PS_SRST_B
• 1-2: Sequencer can control PS_SRST_B
Reset sequencer inhibit
• Open: Sequencer normal operation
• 1-2: Sequencer inhibit (resets stay
asserted)
www.xilinx.com
Chapter 2: Board Setup and Configuration
Table 2-2
(for default jumper
Default
2-3
1-2
1-2
1-2
1-2
Open
Send Feedback
Schematic
Page
3
3
3
12
12
12
15