How to program the adjustab...
6.3.22 Analog I/O Option MCB 109 26-**
Par.
Parameter description
No. #
26-0* Analog I/O Mode
26-00
Terminal X42/1 Mode
26-01
Terminal X42/3 Mode
26-02
Terminal X42/5 Mode
26-1* Analog Input X42/1
26-10
Terminal X42/1 Low Voltage
26-11
Terminal X42/1 High Voltage
26-14
Term. X42/1 Low Ref./Feedb. Value
6
6
26-15
Term. X42/1 High Ref./Feedb. Value
26-16
Term. X42/1 Filter Time Constant
26-17
Term. X42/1 Live Zero
26-2* Analog Input X42/3
26-20
Terminal X42/3 Low Voltage
26-21
Terminal X42/3 High Voltage
26-24
Term. X42/3 Low Ref./Feedb. Value
26-25
Term. X42/3 High Ref./Feedb. Value
26-26
Term. X42/3 Filter Time Constant
26-27
Term. X42/3 Live Zero
26-3* Analog Input X42/5
26-30
Terminal X42/5 Low Voltage
26-31
Terminal X42/5 High Voltage
26-34
Term. X42/5 Low Ref./Feedb. Value
26-35
Term. X42/5 High Ref./Feedb. Value
26-36
Term. X42/5 Filter Time Constant
26-37
Term. X42/5 Live Zero
26-4* Analog Out X42/7
26-40
Terminal X42/7 Output
26-41
Terminal X42/7 Min. Scale
26-42
Terminal X42/7 Max. Scale
26-43
Terminal X42/7 Bus Control
26-44
Terminal X42/7 Timeout Preset
26-5* Analog Out X42/9
26-50
Terminal X42/9 Output
26-51
Terminal X42/9 Min. Scale
26-52
Terminal X42/9 Max. Scale
26-53
Terminal X42/9 Bus Control
26-54
Terminal X42/9 Timeout Preset
26-6* Analog Out X42/11
26-60
Terminal X42/11 Output
26-61
Terminal X42/11 Min. Scale
26-62
Terminal X42/11 Max. Scale
26-63
Terminal X42/11 Bus Control
26-64
Terminal X42/11 Timeout Preset
6-64
VLT AQUA 12-Pulse High Power Instruction Manual
Default value
4 set-up
[1] Voltage
All set-ups
[1] Voltage
All set-ups
[1] Voltage
All set-ups
0.07 V
All set-ups
10.00 V
All set-ups
0.000 N/A
All set-ups
100.000 N/A
All set-ups
0.001 s
All set-ups
[1] Enabled
All set-ups
0.07 V
All set-ups
10.00 V
All set-ups
0.000 N/A
All set-ups
100.000 N/A
All set-ups
0.001 s
All set-ups
[1] Enabled
All set-ups
0.07 V
All set-ups
10.00 V
All set-ups
0.000 N/A
All set-ups
100.000 N/A
All set-ups
0.001 s
All set-ups
[1] Enabled
All set-ups
[0] No operation
All set-ups
0.00%
All set-ups
100.00%
All set-ups
0.00%
All set-ups
0.00%
1 set-up
[0] No operation
All set-ups
0.00%
All set-ups
100.00%
All set-ups
0.00%
All set-ups
0.00%
1 set-up
[0] No operation
All set-ups
0.00%
All set-ups
100.00%
All set-ups
0.00%
All set-ups
0.00%
1 set-up
®
MG.20.Y1.22 - VLT
is a registered Danfoss trademark
Change during
Conver-
operation
sion index
TRUE
-
TRUE
-
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-3
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
Type
Uint8
Uint8
Uint8
Int16
Int16
Int32
Int32
Uint16
Uint8
Int16
Int16
Int32
Int32
Uint16
Uint8
Int16
Int16
Int32
Int32
Uint16
Uint8
Uint8
Int16
Int16
N2
Uint16
Uint8
Int16
Int16
N2
Uint16
Uint8
Int16
Int16
N2
Uint16