How to program the adjustab...
6.3.18 Ext. Closed-loop 21-**
Par. No.
Parameter description
#
21-0* Ext. CL Autotuning
21-00
Closed-loop Type
21-01
PID Performance
21-02
PID Output Change
21-03
Minimum Feedback Level
21-04
Maximum Feedback Level
21-09
PID Auto Tuning
21-1* Ext. CL 1 Ref./Fb.
21-10
Ext. 1 Ref./Feedback Unit
21-11
Ext. 1 Minimum Reference
21-12
Ext. 1 Maximum Reference
21-13
Ext. 1 Reference Source
21-14
Ext. 1 Feedback Source
21-15
Ext. 1 Setpoint
21-17
Ext. 1 Reference [Unit]
21-18
Ext. 1 Feedback [Unit]
21-19
Ext. 1 Output [%]
21-2* Ext. CL 1 PID
21-20
Ext. 1 Normal/Inverse Control
21-21
Ext. 1 Proportional Gain
21-22
Ext. 1 Integral Time
21-23
Ext. 1 Differentiation Time
21-24
Ext. 1 Dif. Gain Limit
21-3* Ext. CL 2 Ref./Fb.
21-30
Ext. 2 Ref./Feedback Unit
21-31
Ext. 2 Minimum Reference
21-32
Ext. 2 Maximum Reference
21-33
Ext. 2 Reference Source
21-34
Ext. 2 Feedback Source
21-35
Ext. 2 Setpoint
21-37
Ext. 2 Reference [Unit]
21-38
Ext. 2 Feedback [Unit]
21-39
Ext. 2 Output [%]
21-4* Ext. CL 2 PID
21-40
Ext. 2 Normal/Inverse Control
21-41
Ext. 2 Proportional Gain
21-42
Ext. 2 Integral Time
21-43
Ext. 2 Differentiation Time
21-44
Ext. 2 Dif. Gain Limit
VLT AQUA 12-Pulse High Power Instruction Manual
Default value
[0] Auto
[0] Normal
0.10 N/A
-999999.000 N/A
999999.000 N/A
[0] Disabled
All set-ups
[0]
All set-ups
0.000 ExtPID1Unit
All set-ups
100.000 ExtPID1Unit
All set-ups
[0] No function
All set-ups
[0] No function
All set-ups
0.000 ExtPID1Unit
All set-ups
0.000 ExtPID1Unit
All set-ups
0.000 ExtPID1Unit
All set-ups
0 %
All set-ups
[0] Normal
All set-ups
0.50 N/A
All set-ups
20.00 s
All set-ups
0.00 s
All set-ups
5.0 N/A
All set-ups
[0]
All set-ups
0.000 ExtPID2Unit
All set-ups
100.000 ExtPID2Unit
All set-ups
[0] No function
All set-ups
[0] No function
All set-ups
0.000 ExtPID2Unit
All set-ups
0.000 ExtPID2Unit
All set-ups
0.000 ExtPID2Unit
All set-ups
0 %
All set-ups
[0] Normal
All set-ups
0.50 N/A
All set-ups
20.00 s
All set-ups
0.00 s
All set-ups
5.0 N/A
All set-ups
®
MG.20.Y1.22 - VLT
is a registered Danfoss trademark
4 set-up
Change during
operation
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
2 set-ups
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
TRUE
Conver-
Type
sion index
-
Uint8
-
Uint8
-2
Uint16
-3
Int32
-3
Int32
-
Uint8
-
Uint8
-3
Int32
-3
Int32
-
Uint8
-
Uint8
-3
Int32
-3
Int32
-3
Int32
0
Int32
-
Uint8
-2
Uint16
-2
Uint32
-2
Uint16
-1
Uint16
-
Uint8
-3
Int32
-3
Int32
-
Uint8
-
Uint8
-3
Int32
-3
Int32
-3
Int32
0
Int32
-
Uint8
-2
Uint16
-2
Uint32
-2
Uint16
-1
Uint16
6-57
6
6
Need help?
Do you have a question about the VLT AQUA Drive FC 200 and is the answer not in the manual?
Questions and answers