General Specifications
Line Power Supply 3 x 525–690V AC
Typical Shaft output at 550 V [kW]
Typical Shaft output at 575 V [HP]
Typical Shaft output at 690 V [kW]
IP21/Nema 1 and IP54/Nema 12 Drive
Types without/with options cabinet
Output current
Continuous
(at 550 V) [A]
Intermittent (60 sec overload)
(at 550 V) [A]
Continuous
(at 575/690 V) [A]
Intermittent (60 sec overload)
(at 575/690 V) [A]
Continuous KVA
(at 550 V) [KVA]
Continuous KVA
(at 690 V) [KVA]
Max. input current
Continuous
(at 550 V) [A]
Continuous
(at 575 V) [A]
Continuous
(at 690 V) [A]
2
2)
Max. cable size, motor [mm
(AWG
)]
2
Max. cable size, line power [mm
(AWG
2
2)
Max. cable size, brake [mm
(AWG
)
Max. external electrical fuses [A] 1
Estimated power loss
at 600 V [W]
4)
Estimated power loss
4)
at 690V [W]
63/64 Max added losses CB or Disconnect
& Contactor
Max panel options losses
Weight,
Unit Size IP21, IP 54 [kg]
Weight, Rectifier Module [kg]
Weight, Inverter Module [kg]
4)
Efficiency
Output frequency
Heatsink overtemp. trip
Power card ambient trip
* Heavy Duty = 160% torque during 60 sec., Light Duty = 110% torque during 60 sec.
1) For type of fuse, see section Fuses.
2) American Wire Gauge.
3) Measured using 16.4 ft. [5 m] shielded motor cables at rated load and rated frequency.
4) The typical power loss is at nominal load conditions and expected to be within +/-15% (tolerance relates to
variety in voltage and cable conditions).
Values are based on a typical motor efficiency (eff2/eff3 border line). Motors with lower efficiency will also add to
the power loss in the adjustable frequency drive and opposite.
If the switching frequency is increased compared to the default setting, the power losses may rise significantly.
LCP and typical control card power consumptions are included. Further options and customer load may add up to
30W to the losses. (Though typical, only 4 W extra for a fully loaded control card, or options for slot A or slot B,
each.)
Although measurements are made with state of the art equipment, some measurement inaccuracy must be
allowed for (+/-5%).
VLT AQUA 12-Pulse High Power Instruction Manual
560
750
710
F10/F11
763
839
730
803
727
872
743
711
711
2)
)]
10771
11315
427
1004/ 1299
102
102
®
MG.20.Y1.22 - VLT
is a registered Danfoss trademark
670
950
800
F10/F11
889
978
850
935
847
1016
866
828
828
8x150
(8x300 mcm)
6x120
(6x250 mcm)
4x185
(4x350 mcm)
900
12272
12903
532
400
1004/ 1299
102
102
0.98
0–500 Hz
185°F [85°C]
154.4°F [68°C]
750
1050
900
F10/F11
988
1087
945
1040
941
1129
7
962
920
920
13835
14533
615
1004/ 1299
102
136
7-9
7