Reference / Ramps 3 - Danfoss VLT AQUA Drive FC 200 Instruction Manual

12-pulse high power
Hide thumbs Also See for VLT AQUA Drive FC 200:
Table of Contents

Advertisement

How to program the adjustab...

6.3.5 Reference / Ramps 3-**

Par. No.
Parameter description
#
3-0* Reference Limits
3-02
Minimum Reference
3-03
Maximum Reference
3-04
Reference Function
3-1* References
3-10
Preset Reference
3-11
Jog Speed [Hz]
6
6
3-13
Reference Site
3-14
Preset Relative Reference
3-15
Reference 1 Source
3-16
Reference 2 Source
3-17
Reference 3 Source
3-19
Jog Speed [RPM]
3-4* Ramp 1
3-41
Ramp 1 Ramp-up Time
3-42
Ramp 1 Ramp-down Time
3-5* Ramp 2
3-51
Ramp 2 Ramp-up Time
3-52
Ramp 2 Ramp-down Time
3-8* Other Ramps
3-80
Jog Ramp Time
3-81
Quick Stop Ramp Time
3-84
Initial Ramp Time
3-85
Check Valve Ramp Time
Check Valve Ramp End Speed
3-86
[RPM]
Check Valve Ramp End Speed
3-87
[HZ]
3-88
Final Ramp Time
3-9 * Digital Potentiometer
3-90
Step Size
3-91
Ramp Time
3-92
Power Restore
3-93
Maximum Limit
3-94
Minimum Limit
3-95
Ramp Delay
6-40
VLT AQUA 12-Pulse High Power Instruction Manual
Default value
4 set-up
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] Sum
All set-ups
0.00%
All set-ups
ExpressionLimit
All set-ups
[0] Linked to Hand /
Auto
All set-ups
0.00%
All set-ups
[1] Analog input 53
All set-ups
[0] No function
All set-ups
[0] No function
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
2 set-ups
0.00 s
All set-ups
0.00 s
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0.00 s
All set-ups
0.10%
All set-ups
1.00 s
All set-ups
[0] Off
All set-ups
100 %
All set-ups
0 %
All set-ups
ExpressionLimit
All set-ups
®
MG.20.Y1.22 - VLT
is a registered Danfoss trademark
Change during
Conver-
operation
sion index
TRUE
-3
TRUE
-3
TRUE
-
TRUE
-2
TRUE
-1
TRUE
-
TRUE
-2
TRUE
-
TRUE
-
TRUE
-
TRUE
67
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
67
TRUE
-1
TRUE
-2
TRUE
-2
TRUE
-2
TRUE
-
TRUE
0
TRUE
0
TRUE
-3
Type
Int32
Int32
Uint8
Int16
Uint16
Uint8
Int32
Uint8
Uint8
Uint8
Uint16
Uint32
Uint32
Uint32
Uint32
Uint32
Uint32
Uint16
Uint16
Uint16
Uint16
Uint16
Uint16
Uint32
Uint8
Int16
Int16
TimD