Commissioning
Illustration 6.22 Local Area Connection 2 Properties
Disable the IPv4 Checksum offload on the network
interfaces as described in chapter 6.5.4.1 Network Settings
for Indirect Communication.
How to set the correct Ethernet POWERLINK
address:
1.
Open the Network and Sharing Center.
2.
On the left, click on Change adapter settings.
3.
Right-click on the network interface used for
fieldbus communication and select Properties.
4.
Click on Internet Protocol Version 4 (TCP/IPv4) (the
checkbox must be checked) and then click on
Properties.
5.
Select Use the following IP address and use
192.168.100.240 as the IP address and
255.255.255.0 as the subnet mask. Leave all other
fields empty.
MG75K102
Operating Instructions
Illustration 6.23 Internet Protocol Version 4 (TCP/IPv4)
Properties
6.5.4.3 Network Settings for Direct
No EtherCAT
needs to be performed on the ISD Toolbox host PC.
®
master IP
Danfoss A/S © 12/2015 All rights reserved.
Communication with EtherCAT
®