Maintenance, Decommissioning, And Disposal; Maintenance Tasks - Danfoss VLT Integrated Servo Drive ISD 510 System Operating Instructions Manual

Hide thumbs Also See for VLT Integrated Servo Drive ISD 510 System:
Table of Contents

Advertisement

Maintenance, Decommissionin...

10 Maintenance, Decommissioning, and Disposal

WARNING
HIGH VOLTAGE
Potentially lethal voltage is present on the connectors.
Before working on the power connectors (disconnecting
or connecting the cable), disconnect the SAB from the
mains and wait for the discharge time to elapse.
WARNING
DISCHARGE TIME
The servo drives and the SAB contain DC-link capacitors
that remain charged for some time after the mains
supply is switched off at the SAB. Failure to wait the
specified time after power has been removed before
performing service or repair work could result in death
or serious injury.
To avoid electrical shock, fully disconnect the
SAB from the mains and wait for at least the
time listed in Table 10.1 for the capacitors to
fully discharge before carrying out any
maintenance or repair work on the ISD 510
servo system or its components.
Number
Minimum waiting time (minutes)
0–64 servo drives
10
Table 10.1 Discharge Time
MG75K102
Operating Instructions

10.1 Maintenance Tasks

The servo drives are largely maintenance free. Only the
shaft seal (if used) is subject to wear.
The maintenance tasks listed in Table 10.2 can be
performed by qualified personnel (see chapter 2.5 Qualified
Personnel). No other tasks are required.
Component Maintenance
Servo drive Carry out a
Shaft seal
Hybrid
cable
Mechanical
holding
brake
(optional)
Functional
safety
SAB
Table 10.2 Overview of Maintenance Tasks
1) A shorter interval may be necessary depending on the application.
Contact Danfoss for more information.
Danfoss A/S © 12/2015 All rights reserved.
Maintenance
Instruction
task
interval
Every 6
Check for any
visual
months
abnormalities on the
inspection.
surface of the servo
drive.
Check the
Every 6
If damaged, replace
condition and
the shaft seal.
months
1)
check for
leakage.
Check for
Every 6
If damaged or worn:
damage and
months
Replace the hybrid
wear.
cable (see
chapter 10.3.1 Cable
Replacement).
Check the
Every 6
Ensure that the brake
brake.
months
can achieve the
holding torque as
detailed in
chapter 3.2.2.2 Brake
(Optional).
Perform a
Every 12
Activate STO and
system power
months
check the status with
cycle and
the PLC. See
check the
chapter 8 ISD Safety
STO function.
Concept for further
information.
Check the
Every 12
Check that the fan
fan.
months
can turn and remove
any dust or dirt.