Diagnostics
Code
Name
0x8694 Homing
error on
start homing
method
0x8695 Homing
error
distance
0xFF01
Mechanical
brake failure
0xFF02
Short circuit
in
mechanical
brake
control
0xFF0A External
interface
power
failure
9
9
0xFF60
Timing
violation 1
0xFF61
Timing
violation 2
0xFF62
Timing
violation 3
0xFF63
Timing
violation 4
0xFF64
Timing
violation 5
0xFF65
Timing
violation 6
0xFF70
Firmware:
Package
description
mismatch
0xFF71
Firmware:
Power cycle
needed
76
®
VLT
Integrated Servo Drive ISD
Severity
Description
LCP name
(Warning/
Error/Trip
lock)
Warning
Could not
Homing
start homing
method fail
method (for
example
drive not in
standstill).
Warning
Homing
Homing
distance
distance
reached.
Trip lock
No brake or
brake mech
wire failure.
fail
Trip lock
Short circuit
brake mech
in brake
short
control.
Error
External
ext IF pwr
interface
fail
power
supply
failure.
Trip lock
Contact
timing err 1
Danfoss.
Trip lock
Contact
timing err 2
Danfoss.
Trip lock
Contact
timing err 3
Danfoss.
Trip lock
Contact
timing err 4
Danfoss.
Trip lock
Contact
timing err 5
Danfoss.
Trip lock
Contact
timing err 6
Danfoss.
Trip lock
Firmware
FW pack err
found does
not match
the package
description.
Warning,
Firmware
need
error
update
powercycle
transfer is
completed
but a power
cycle is
required
before the
new
firmware is
active.
Danfoss A/S © 12/2015 All rights reserved.
®
510 System
Code
Name
Severity
(Warning/
Error/Trip
lock)
0xFF72
Firmware:
Warning,
Update
error
started
0xFF80
STO active
Error
while drive
enabled
0xFF81
STO
Trip lock
mismatch
0xFF85
P_STO error
Trip lock
0xFF90
Guide value
Error
reversed
0xFF91
Guide value
Error
implausible
Table 9.2 Error Codes for Servo Drive
Description
LCP name
Firmware
FW update
update in
progress.
The warning
becomes an
error when
an attempt
is made to
enable the
drive in this
state.
STO
STO active
activated
while servo
drive was
enabled or
tried to
enable while
STO active.
Dual
STO
diagnosis of
mismatch
STO voltage
not
plausible.
P_STO
P_STO error
voltage on
power card
not within
limits.
Position
guide val rev
guide value
went
backwards
while servo
drive in CAM
mode.
Increments
guide val
between
impl
succeeding
values too
big.
MG75K102