Diagnostics
Fault
Possible cause
(Unusual) running
Defective bearing.
noises
Defects on
connected
mechanics.
Incorrect control
loop parameters.
System fuse
Short circuit.
blows, circuit
Incorrect control
breaker trips, or
loop parameters.
drive protection
trips immediately.
Drive speed drops
Drive is running at
sharply under
current limit.
load.
Drive is running
with incorrect
parameters.
Brake does not
Brake control
release.
defective.
Holding brake
Mechanical brake
does not hold the
defective.
servo drive.
Shaft load exceeds
the holding torque
of the brake.
Brake
Software error.
engagement
delayed.
Noises when
Mechanical brake
power-off brake
damaged.
engaged.
LEDs do not light
No power supply.
up.
Error 0xFF91
Increments between
occurs.
succeeding values too
big.
Table 9.1 Troubleshooting Servo Drive

9.2.2 Error Codes

Code
Name
Severity
(Warning/
Error/Trip
lock)
0x0000 No error
Error
0x1000 Generic
Error
application
error
0x2310 Overcurrent
Error
on output
MG75K102
Operating Instructions
Possible solution
Check the shaft.
Check for loose
mechanical
components on
the attached
mechanics.
Check the
parameter
settings.
Check the wiring.
Contact Danfoss.
Check the
application.
Check the
parameter
settings.
Contact Danfoss.
Contact Danfoss.
Contact Danfoss.
Contact Danfoss.
Check the power
supply.
Check for velocity or
guide value plausi-
bility distance.
Description
LCP name
No error.
Generic
generic err
application
error.
Overcurrent
overcurr out
on output.
Danfoss A/S © 12/2015 All rights reserved.
Code
Name
Severity
(Warning/
Error/Trip
lock)
0x239B Overload on
Warning,
output (I2T)
error
0x3210 DC link
Error
overvoltage
0x3220 DC link
Error
undervoltag
e
0x4290 Overtem-
Error
perature:
Power
module
0x4291 Overtem-
Error
perature:
Control card
0x4295 Overtem-
Error
perature:
Power card
0x4310 Overtem-
Error
perature:
Motor
0x5112 UAUX
Error, trip
undervoltag
lock
e
0x5530 EE
Trip lock
Checksum
Error
(parameter
missing)
0x6320 Parameter
Trip lock
error
0x7320 Internal
Trip lock
position
sensor error
0x7380 External
Error
position
sensor error
0x8693 Homing
Warning
error on
entering
homing
mode
Description
LCP name
overload
2
I
t thermal
state.
Overvoltage
UDC
on DC-link
overvolt
voltage
Undervoltag
UDC
e on DC-link
undervolt
voltage.
Overtem-
overtemp
perature on
PM
power
module.
Overtem-
overtemp CC
perature on
control PCB.
Overtem-
overtemp PC
perature on
power PCB.
Overtem-
overtemp
perature on
motor
motor.
Undervoltag
undervolt
e on
UAUX
auxiliary
voltage.
Missing
config err
parameter in
internal
drive config-
uration.
An internal
param err
parameter
has an
invalid value.
Absolute
int sensor
position
err
sensor error.
External
ext sensor
encoder
err
data could
not be read.
Could not
Homing
enter
mode fail
homing
mode (for
example
velocity not