Commissioning
8.
Right-click and select Change Multi Link....
9.
In the Attach Variable 36.0 Byte(s) (Output) window
select [PLC-Configuration → MyFirstIsd510Project
→ Standard → .myAxis.RPDO].
Click on OK.
10.
Right-click on WcState via [I/O-Configuration →
11.
I/O Devices → Device1 (EtherCAT
Servo Access Box L1) → Drive2 (VLT
Integrated Servo Drive) → WcState] and select
Change Link....
12.
In the Attach Variable State (Input) window select
[PLC-Configuration → MyFirstIsd510Project →
Standard → .myAxis.WcState.
13.
Click on OK.
Right-click on State via [I/O-Configuration → I/O
14.
Devices → Device1 (EtherCAT
Servo Access Box L1) → Drive2 (VLT
Integrated Servo Drive) → InfoData] and select
Change Link....
15.
In the Attach Variable State (Input) window select
[PLC-Configuration → MyFirstIsd510Project →
Standard → .myAxis.State.
16.
Click on OK.
Right-click on netId via [I/O-Configuration → I/O
17.
Devices → Device1 (EtherCAT
Servo Access Box L1) → Drive2 (VLT
Integrated Servo Drive) → InfoData → AdsAddr]
and select Change Link....
18.
In the Attach Variable netId (Input) window select
[PLC-Configuration → MyFirstIsd510Project →
Standard → .myAxis.AmsNetId.].
19.
Click on OK.
Right-click on port via [I/O-Configuration → I/O
20.
Devices → Device1 (EtherCAT
Servo Access Box L1) → Drive2 (VLT
Integrated Servo Drive) → InfoData → AdsAddr]
and select Change Link....
21.
In the Attach Variable port (Input) window select
[PLC-Configuration → MyFirstIsd510Project →
Standard → .myAxis.NodeNumber.].
22.
Click on OK.
MG75K102
Operating Instructions
®
) → Box1 (VLT
®
®
ISD 510
Illustration 6.15 Attaching Inputs and Outputs to the Physical
Data Points
®
) → Box1 (VLT
®
NOTICE
®
ISD 510
Repeat the steps 2–22 for Box 1 (VLT
L1) and the instance mySAB.
To transfer the mappings back to the PLC program, select
Activate Configuration... in menu item Actions.
After a rebuild in TwinCAT
configuration is according to Illustration 6.16 (here myAxis
and mySecondAxis are instances of AXIS_REF_ISD51x and
mySAB is an instance of SAB_REF). The concrete addresses
®
®
) → Box1 (VLT
can be different.
®
ISD 510
®
) → Box1 (VLT
®
®
ISD 510
Illustration 6.16 TwinCAT
Servo Drives and an SAB
Danfoss A/S © 12/2015 All rights reserved.
®
Servo Access Box
®
®
PLC Control, the TwinCAT
®
Configuration: I/O Mapping of 2
6
6
53