C. EtherNet/IP Objects of the CPX-FB36
C.4.6 "Generic Parameter Object"
Procedure for paramet­
erisation
C-28
Object class:
Instances:
The rule is: Instance number = Module number + 1
This object enables general access to the module parameters
of all existing and future CPX modules.
Use this object for parameterising modules with word or
double-word parameters.
Examples of modules with word or double-word parameters:
Analogue input module CPX-4AE-I
Temperature module CPX-4AE-T
CPX-CP interface
Three parameter types can be accessed via the attributes of
the general module parameter object:
byte parameters
word parameters
double-word parameters
1. Take the function number of the parameter to be set
from the description for the module.
2. Search for the function number in the Tab. C/30 (byte/
word parameter) or Tab. C/31 (double-word parameter).
3. Read the corresponding attribute number from the re­
spective table.
Examples for parameterisation with the general module para­
meter object can be found in chapter C.5.2.
101
d
1
48
...
through the attributes 1
through the attributes 65
through the attributes 129
Festo CPX-FB36-EN en 1611a English
64
...
127
...
189
...