Contents and general instructions
Safety instructions
Festo CPX-FB36-EN en 1611a English
Before assembly or installation work, switch off the power
supply, switch off the compressed air supply, exhaust any
pneumatic components.
For the electrical power supply, only use PELV circuits in
accordance with IEC 60204-1/EN 60204-1.
Note the information on installation and power supply as
well as on potential equalisation (earthing measures) in
the CPX system description (è P.BE-CPX-SYS-...).
Observe the handling specifications for electrostatically
sensitive devices.
Seal unused connections with cover caps to achieve the
required degree of protection.
Use connection technology with the required degree of
protection.
Observe the specifications in the CPX system description,
in the descriptions of the valve terminal used as well as in
the assembly instructions of the individual components.
Observe the instructions for correctly mounting the CPX
terminal.
Place only a completely mounted and wired CPX terminal
into operation.
Only switch on the compressed air and load voltage if the
system has been professionally installed, configured and
parameterised.
Make sure that nobody enters the positioning range of
the actuators.
Switching off the compressed air or load voltage is not a suit­
able locking mechanism. Unintentional movement of actuat­
ors may occur in the event of a malfunction.