Tcp/Ip Interface Object - Festo CPX-FB36 Instruction Manual

Bus node network protocol ethernet/ip modbus tcp industrial ethernet 2-port
Hide thumbs Also See for CPX-FB36:
Table of Contents

Advertisement

C. EtherNet/IP Objects of the CPX-FB36
C.2.3 "TCP/IP Interface Object"
C-10
Object class:
245
Instances:
1
The network settings of a device are configured with the TCP/
IP Interface Object.
Attr.
Access
Description
no.
1
Get
Status (Interface Status)
2
Get
Configuration Capability
Bit 5:
Bit 6:
Bit 7:
3
Get/Set
Configuration Control
4
Get
Physical Link Object
– Path Size
– Path
5
Get/Set
Interface Configuration
– IP Address
– Network Mask
– Gateway Address
– Name Server
– Name Server 2
– Domain Name
6
Get/Set
HostName
Tab. C/8:
Network settings with TCP/IP Interface Object -
part 1
d
Hardware configurable
Interface configuration
change requires reset
AcdCapable
Festo CPX-FB36-EN en 1611a English
Type
DWORD
DWORD
DWORD
STRUCT of
UINT +
Padded
EPATH
STRUCT of
UDINT
UDINT
UDINT
UDINT
UDINT
STRING
STRING

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents