Confirmation With A Windows Computer - Toshiba TSL3000 Communications Manual

Ts3000 series robot controller
Hide thumbs Also See for TSL3000:
Table of Contents

Advertisement

series Robot Controller
(3) Cautions
 Check that the Ethernet cable between the controller and external device is
connected correctly.
 Use a cross connect cable if connecting the robot controller directly to an
external device, and use a straight cable if the connection passes through a
hub.
 After making any parameter settings, turn the power off and then on again to
enable the new settings.
5.2.4

Confirmation with a Windows Computer

This describes how to confirm the connection using the DOS command "ping".
From the Start menu in Windows, go to the Command Prompt, and specify the IP
address of the robot controller as shown below.
C:¥> ping Robot controller IP address
If there is a transmission problem, the result "unreachable" or "Request Time out" is
displayed as shown in Figure 5.2.
If transmission is performed normally, the result "Reply from ..." is displayed as
shown in Figure 5.3.
Established
Fin-Wait1
Fin-Wait2
Close wait
Closing
Last ACK
Time Wait
– 39 –
COMMUNICATION MANUAL
STE 80722

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tsl3000eTs3100Ts3000

Table of Contents