Confirmation With A Windows Computer - Toshiba TS3000 Series Instruction Manual

Vertical articulated robot system controller
Hide thumbs Also See for TS3000 Series:
Table of Contents

Advertisement

series Robot Controller
(3) Cautions
 Check that the Ethernet cable between the controller and external device is
connected correctly.
 Use a cross connect cable if connecting the robot controller directly to an
external device, and use a straight cable if the connection passes through a
hub.
 After making any parameter settings, turn the power off and then on again to
enable the new settings.
5.2.4

Confirmation with a Windows Computer

This describes how to confirm the connection using the DOS command "ping".
From the Start menu in Windows, go to the Command Prompt, and specify the IP
address of the robot controller as shown below.
C:¥> ping Robot controller IP address
If there is a transmission problem, the result "unreachable" or "Request Time out" is
displayed as shown in Figure 5.2.
If transmission is performed normally, the result "Reply from ..." is displayed as
shown in Figure 5.3.
Established
Fin-Wait1
Fin-Wait2
Close wait
Closing
Last ACK
Time Wait
– 34 –
COMMUNICATION MANUAL
STE 80732