Toshiba TSL3000 Communications Manual page 57

Ts3000 series robot controller
Hide thumbs Also See for TSL3000:
Table of Contents

Advertisement

series Robot Controller
: Automatic Operation Stop
Format
SP
CR
Description
The SP (Automatic Operation Stop) command is given by the host computer to the
controller telling the controller to stop automatic operation. Also, this command
informs the host computer when the controller is stopped. Furthermore, should the
robot be stopped in accordance with any request other than that made by the host
computer, this command will automatically be sent from the controller to the host
computer.
Protocol
Controller
1. Automatic operation stop directive
(1)
Normal operation
(2)
Error
(Host computer → Controller)
OK
CR
NG
CR
– 52 –
COMMUNICATION MANUAL
SP
Host
CR
SP
(Automatic operation
stop directive)
Normal response, program stop
Request not accepted
STE 80722

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tsl3000eTs3100Ts3000

Table of Contents