DataTran Diagnostic
Use only with Datacap Support as necessary to troubleshoot Datatran issues.
1. Turn the control lock to the Z position.
2. Press 5 and CASH to select the Datatran Function menu.
3. Press 8 and CASH; The message "DIAG NUMBER 0" will display.
4. Press the 0 key and then CASH to print a list of diagnostic options:
5. Reselect the Diagnostic option. The message "DIAG NUMBER" will again display.
6. Enter the number of the diagnostic test you wish to perform and press CASH. The report
Sam4s ER-260EJ/256EJ OP Manual v1.20
DATE 5/05/2017 THU
*** DATATRAN SELF TESTS ***
1 – IPTRAN VERSION
4 – CREDIT MID SETTINGS
10- IP ADDRESS
11- DNS TEST
15- PARAM LOAD
40- EEPROM DATA
41- RESET SEQKUENCE NUMBER
CLERK 1
will print.
TIME 10:34
000096 00000