Functions, Settings, Information
E.2 Settings
Addr. Parameter
3437
ADT SynRequest
3438
T U-stable
3440
U-live>
3441
U-dead<
3450
1.AR: START
3451
1.AR: T-ACTION
3453
1.AR Tdead 1Flt
3454
1.AR Tdead 2Flt
3455
1.AR Tdead 3Flt
3456
1.AR Tdead1Trip
3457
1.AR Tdead3Trip
3458
1.AR: Tdead EV.
3459
1.AR: CB? CLOSE
3460
1.AR SynRequest
3461
2.AR: START
3462
2.AR: T-ACTION
3464
2.AR Tdead 1Flt
3465
2.AR Tdead 2Flt
3466
2.AR Tdead 3Flt
3467
2.AR Tdead1Trip
3468
2.AR Tdead3Trip
3469
2.AR: Tdead EV.
3470
2.AR: CB? CLOSE
3471
2.AR SynRequest
3472
3.AR: START
3473
3.AR: T-ACTION
3475
3.AR Tdead 1Flt
3476
3.AR Tdead 2Flt
302
Function
C
Setting Options
Autoreclosure
YES
NO
Autoreclosure
0.10 .. 30.00 sec
Autoreclosure
Autoreclosure
30 .. 90 V
Autoreclosure
Autoreclosure
2 .. 70 V
Autoreclosure
Autoreclosure
YES
NO
Autoreclosure
0.01 .. 300.00 sec
Autoreclosure
0.01 .. 1800.00 sec 1.20 sec
Autoreclosure
0.01 .. 1800.00 sec 1.20 sec
Autoreclosure
0.01 .. 1800.00 sec 0.50 sec
Autoreclosure
0.01 .. 1800.00 sec 1.20 sec
Autoreclosure
0.01 .. 1800.00 sec 0.50 sec
Autoreclosure
0.01 .. 1800.00 sec 1.20 sec
Autoreclosure
YES
NO
Autoreclosure
YES
NO
Autoreclosure
YES
NO
Autoreclosure
0.01 .. 300.00 sec
Autoreclosure
0.01 .. 1800.00 sec 1.20 sec
Autoreclosure
0.01 .. 1800.00 sec 1.20 sec
Autoreclosure
0.01 .. 1800.00 sec 0.50 sec
Autoreclosure
0.01 .. 1800.00 sec 2147483647 sec
Autoreclosure
0.01 .. 1800.00 sec 0.50 sec
Autoreclosure
0.01 .. 1800.00 sec 1.20 sec
Autoreclosure
YES
NO
Autoreclosure
YES
NO
Autoreclosure
YES
NO
Autoreclosure
0.01 .. 300.00 sec
Autoreclosure
0.01 .. 1800.00 sec 1.20 sec
Autoreclosure
0.01 .. 1800.00 sec 1.20 sec
Default Setting
Comments
NO
Request for synchro-
check after 3pole AR
0.10 sec
Supervision time for
dead/live voltage
48 V
Voltage threshold for live
line or bus
30 V
Voltage threshold for
dead line
YES
AR start allowed in this
cycle?
0.20 sec
Action time
Dead time after 1phase
faults
Dead time after 2phase
faults
Dead time after 3phase
faults
Dead time after 1pole trip
Dead time after 3pole trip
Dead time after evolving
fault
NO
CB ready interrogation
before reclosing
NO
Request for synchro-
check after 3pole AR
NO
AR start allowed in this
cycle?
0.20 sec
Action time
Dead time after 1phase
faults
Dead time after 2phase
faults
Dead time after 3phase
faults
Dead time after 1pole trip
Dead time after 3pole trip
Dead time after evolving
fault
NO
CB ready interrogation
before reclosing
NO
Request for synchro-
check after 3pole AR
NO
AR start allowed in this
cycle?
0.20 sec
Action time
Dead time after 1phase
faults
Dead time after 2phase
faults