24 VDC POWER SUPPLY (con't)
ADJUSTMENT
TM
The Sharp SX
Bagger's Power Supply has two
user adjustable settings. These settings are set at
the factory and do not require regular adjustment.
The following steps will guide you through setting
the Power Supply to the factory defaults.
1. Remove the two rear screws and the two front
screws from the Motor Cover (Figure 3-27 and
Figure 3-28).
Figure 3-27. Motor Cover Rear Screws
Figure 3-28. Motor Cover Front Screws
SX™
Service and Maintenance Manual
ELECTRICAL COMPONENTS
2. Locate the 24 VDC Power Supply.
.
3. Locate the red Switch on the side of the Power
4. Set the Voltage Selector Switch to 115V.
3-11
SECTION 3 – COMPONENT REPAIR
Note: The power supply location changes
depending on your version of the Sharp SX
Bagger. The wiring however is exactly the
same
Supply. (Figure 3-29).
Figure 3-29. Voltage Selector Switch
Note: If your region uses 230 VAC as the
standard voltage, a step-down transformer is
required. This will lower the voltage entering
the machine to 115 VAC. Set the Voltage
Selector Switch to 115V regardless of your
region.