Sealpoint Components - Sharp SX 1075 Service Maintenance Manual

Table of Contents

Advertisement

SEALPOINT COMPONENTS

Seal wires, Teflon tape, and anvil rubber are
available together in the Sealer Maintenance Kit
(P/N 960552-01), which is available from Sharp
Packaging Systems Inc.
inexpensive and easy to replace, yet provide great
improvement to the overall quality of the seals
when replaced at regular intervals.
Seal Wire
TESTING
WARNING
Always remove electrical power from the
SX prior to performing any maintenance
on the machine.
TM
If the Sharp SX
will not seal bags, remove the
Teflon tape to expose the seal wire. If the seal wire
is not broken, further troubleshooting is required
(See the Electrical Assembly: Transformers
section to troubleshoot the seal wire circuitry).
ADJUSTMENT
The seal wire is adjustment free.
SX™
Service and Maintenance Manual
SEALER ASSEMBLY
These wear items are
SECTION 3 – COMPONENT REPAIR
REPLACEMENT
1. Remove the front lexan guard (Figure 3-328).
Front Lexan
Guard
Figure 3-328. Guard Identification
2. Completely remove the Teflon tape from the
seal wire area (Figure 3-329).
Teflon Tape
Figure 3-329. Removing the Teflon Tape
3-129