COOLING FAN (con't)
4. Unplug power connection from Cooling Fan
(Figure 3-93).
5. Remove the four screws holding the Cooling
Fan to the Outside Plate (Figure 3-94).
6. Remove the old Cooling Fan.
7. With replacement fan, orientate so that the
airflow direction indicator points towards the
outside of the frame and so that the Cooler Fan
plug is at the top facing you (Figure 3-95).
8. Line up the screw holes in the Outside Plate
with those on the Cooler Fan.
9. With the screws from the old Cooler Fan, re-
attach the new Cooler Fan to the Outside
Plate.
10. Reattach Cooler Fan plug.
11. Replace Motor Cover and Outside Cover.
SX™
Service and Maintenance Manual
SECTION 3 – COMPONENT REPAIR
ELECTRICAL COMPONENTS
3-34
Figure 3-93. Remove Cooling Fan plug
Figure 3-94. Cooling Fan screws
Figure 3-95. Airflow direction indicator