Sharp SX 1075 Service Maintenance Manual page 58

Table of Contents

Advertisement

SOLID STATE RELAY (con't)
ADJUSTMENT
There are no adjustments necessary on the Solid
State Relay.
REPLACEMENT
WARNING
Always remove electrical power from the
SX prior to performing any maintenance
on the machine.
1. Remove the four screws holding the Load
Plate, set Load Plate aside (Figure 3-102).
2. Locate Solid State Relay; remove clear plastic
cover (Figure 3-103).
3. Remove the four wire screws.
4. Remove the two screws holding the Solid State
Relay to the Base Plate and set aside.
5. Remove defective relay.
6. Orientate replacement Solid State Relay so
that connections 3 and 4 are towards the front
of the machine.
7. Screw Solid State Relay down onto Base Plate.
8. Reconnect the four wires and tighten holding
screws (Table 3-1).
9. Snap clear plastic cover over Solid State
Relay.
10. Reattach Load Plate using screws and locking
washers.
SX™
Service and Maintenance Manual
SECTION 3 – COMPONENT REPAIR
ELECTRICAL COMPONENTS
Wire Label
3-38
Figure 3-102. Load Plate Screws
Figure 3-103. Solid State Relay with cover
Wire Color
-
Black
-
Black
91
Dark Blue
Y6
Dark Blue
Table 3-1. Solid State Relay connections
Terminal Number
1
2
3
4
960714-02B © 2007 I2407

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sx 1097Sx 1099Sx 1109Sx 1121Sx 1084Sx 1108

Table of Contents