JAW POSITION SENSORS (con't)
REPLACEMENT
1. Remove the guards identified in Figure 3-365.
Outside
Frame
Guard
Left
Sealer
Guard
Front
Guard
Figure 3-365. Guard Identification
2. Remove the mounting screws for the sensor
bracket that needs replacement. Once free,
access the sensor through the rear of the
machine. Follow the wire routing through the
machine, and remove any wire ties as
necessary.
Jaw Sensor Mounting Screws
Figure 3-366. "Near Home" Sensor Mounting Screw
SX™
Service and Maintenance Manual
SECTION 3 – COMPONENT REPAIR
SEALER ASSEMBLY
3. Locate the 6-position junction box, and unplug
the connector in port 1 for the "Near Home"
Sensor and/or port 2 for the "Home Sensor.
This should free the sensor completely from
the machine.
careful of other wires still in the machine
(Figure 3-367).
Motor
Cover
Load
Plate
4. Remove the sensor mounting screw from the
block, and install the new sensor in the
orientation shown in Figure 3-368.
3-143
Gently pull the wire, being
6-Position
Junction Box
Figure 3-367.Stripper Plate Sensor Plugs
Figure 3-368. Sensor Mounting Block