24 VDC POWER SUPPLY (con't)
12. With one hand, position a small screwdriver on
the voltage adjustment POT (Figure 3-37).
13. Place the black probe on the "V-"contact and
the red probe on the "V+" contact (Figure 3-38).
14. Adjust the POT until your DVOM reads 24.0
VDC.
Note: Depending on your version of the Sharp
TM
SX
Bagger, the Power Supply POT may be
difficult to reach. If this is the case, measure
the voltage, then set the probes aside and
adjust the voltage with a small screwdriver.
Repeat until DVOM indicates 24.0 VDC.
15. Replace Motor Cover.
SX™
Service and Maintenance Manual
ELECTRICAL COMPONENTS
3-15
SECTION 3 – COMPONENT REPAIR
Figure 3-37. Adjusting Power Supply Voltage
Figure 3-38. Testing 24 VDC on Power Supply
960714-02B © 2007 I2407