Transformers - Sharp SX 1075 Service Maintenance Manual

Table of Contents

Advertisement

TRANSFORMERS

TM
The Sharp SX
Bagger uses two "Step-Down"
transformers. One is used for the Seal Wire and the
other is used for the two TM4500 stepper drives.
They are each 0.365 KVA transformers with a
120(P):28(S) voltage ratio. Only replace with equal
or greater KVA rating and same voltage ratio.
TESTING
WARNING
Always remove electrical power from the
SX prior to performing any maintenance
on the machine.
1. Remove the two rear screws and the two front
screws holding the Motor Cover. (Figure 3-58
and Figure 3-59)
Figure 3-58. Motor Cover Front Screws
Figure 3-59. Motor Cover Rear Screws
SX™
Service and Maintenance Manual
ELECTRICAL COMPONENTS
2. Remove Motor Cover and set aside.
3. Remove the four screws holding the Load
4. Locate
3-22
SECTION 3 – COMPONENT REPAIR
Plate, set screws and Load Plate aside (Figure
3-60.)
Figure 3-60. Load Plate Screws
the
transformer
troubleshoot and proceed to that section
(Figure 3-61).
Note:
Transformer
locations
depending on your version of the SX. The
Stepper Drive transformer's wires terminate in
a terminal block. The Seal Wire transformer is
connected to the Solid State Relay and Seal
Wire.
Stepper Drive
Solid State Relay
Seal Wire
Figure 3-61. Transformer locations for the SX
1108 and 1109
you
wish
to
will
change
960714-02B © 2007 I2407

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sx 1097Sx 1099Sx 1109Sx 1121Sx 1084Sx 1108

Table of Contents