Sharp SX 1075 Service Maintenance Manual page 27

Table of Contents

Advertisement

FUSES (con't)
ADJUSTMENT
There are no adjustments necessary on fuses.
REPLACEMENT
A blown fuse can be an indication of a larger issue
with the electronics in the Sharp SX
NOT REPLACE A BLOWN FUSE WITH A
LARGER AMPERAGE FUSE. If you continue to
blow fuses, troubleshoot other components to
discover problem.
WARNING
Always remove electrical power from the
SX prior to performing any maintenance
on the machine.
1. Remove Frame Cover Screws; there are six
screws to remove (Figure 3-18).
2. Locate the defective fuse. The 10 Amp system
fuse is on the left and the 5 amp stepper drive
fuse is on the right.
3. Pivot fuse holder to gain access to the Fuse
Access Door (Figure 3-19).
4. Open Fuse Access Door and remove fuse
(Figure 3-20).
5. Replace with a 5x20mm fuse of the same
amperage.
6. Close access door and pivot fuse holder back
into its home position.
7. Replace Frame Cover with screws and locking
washers.
SX™
Service and Maintenance Manual
ELECTRICAL COMPONENTS
TM
Bagger. DO
3-7
SECTION 3 – COMPONENT REPAIR
Figure 3-18. Frame Cover Screws
Figure 3-19. Pivot Fuse Holder
Figure 3-20. Fuse Access Door