24 VDC POWER SUPPLY (con't)
REPLACEMENT
1. Turn off the Sharp SX
all power cords.
WARNING
Always remove electrical power from the
SX prior to performing any maintenance
on the machine.
2. Remove the two rear screws and the two front
screws from the Motor Cover (Figure 3-32 and
Figure 3-33).
Figure 3-32. Motor Cover Rear Screws
Figure 3-33. Motor Cover Front Screws
SX™
Service and Maintenance Manual
ELECTRICAL COMPONENTS
TM
Bagger and disconnect
SECTION 3 – COMPONENT REPAIR
3. Disconnect all wires from the Power Supply.
4. Remove the three screws holding the Power
Supply to the frame. (Figure 3-34).
Figure 3-34. Power Supply screw locations
5. Remove the defective Power Supply and set
aside.
6. With new power supply, check that the Voltage
Selector Switch is set to 115 VAC (Figure 3-
35).
Note: If your region uses 230 VAC as the
standard voltage, a step-down transformer is
required. This will lower the voltage entering
the machine to 115 VAC. Set the Voltage
Selector Switch to 115V regardless of your
region.
Figure 3-35. Voltage Selector Switch
3-13
960714-02B © 2007 I2407