Sharp SX 1075 Service Maintenance Manual page 159

Table of Contents

Advertisement

STRIPPER PLATE SENSORS (con't)
9. Follow the sensor cable back through the
machine, removing wire ties as necessary to
free the sensor from the machine. Unplug the
sensor from the 6-position junction box. The
left stripper plate sensor is plugged into
receptacle 5 (Figure 3-364).
Figure 3-353.Stripper Plate Sensor Plugs
10. Remove the sensor from the mounting block,
and install the new sensor (Figure 3-354).
Figure 3-354. Sensor Mounting Block
SX™
Service and Maintenance Manual
SEALER ASSEMBLY
Left Sensor Plug
(Receptacle 5)
SECTION 3 – COMPONENT REPAIR
11. Reinstall the left sensor and mounting block
into the machine (Figure 3-355).
Left Sensor
in Machine
Figure 3-355. Installing the Left Plate Sensor
Note: Side Plate Shown Clear for Clarity
12. Route the sensor cable through the machine,
following the same path the previous cable
took. Plug the sensor into receptacle 5 on the
6-position junction box. Secure sensor cables
to bundles inside the machine to keep wires
free of moving parts.
Setting Sensor Position (Both Sides)
13. Follow the steps outlined in the "Adjustment"
section to position the sensors in the correct
location.
14. Reinstall all guards removed in the previous
steps.
3-139