LINE FILTER (con't)
ADJUSTMENT
There are no adjustments necessary on the Line
Filter.
REPLACEMENT
WARNING
Always remove electrical power from the
SX prior to performing any maintenance
on the machine.
1. Remove the six screws holding the Frame
Cover, set screws and Frame Cover aside
(Figure 3-45).
Figure 3-45. Frame Cover Screws
2. Remove the seven screws holding the Mandrel
Support Plate, set screws and plate aside
(Figure 3-46 & 3-47).
Note: There are seven screws holding the
Mandrel
Support
removing bottom screws and never work on an
unstable platform.
3. Remove the three spade connectors from the
Line Filter (Figure 3-48).
SX™
Service and Maintenance Manual
ELECTRICAL COMPONENTS
Plate.
Use
care
when
SECTION 3 – COMPONENT REPAIR
Figure 3-46. Mandrel Support screws
Figure 3-47. Mandrel Support Plate Bottom
Figure 3-48. Remove three spade connectors
3-18
Mandrel
Support
screws
Plate
screws
Screws
960714-02B © 2007 I2407