Sharp SX 1075 Service Maintenance Manual page 158

Table of Contents

Advertisement

STRIPPER PLATE SENSORS (con't)
5. Reinstall the sensor and mounting block into
the machine. The sensing area of the sensor
is to be oriented to the top of the machine
(Figure 3-350).
Figure 3-350. Installing the Right Plate Sensor
Note: Side Plate Shown Clear for Clarity
6. Route the sensor cable through the machine,
following the same path the previous cable
took. Plug the sensor into receptacle 6 on the
6-position junction box. Secure sensor cables
to bundles inside the machine to keep wires
free of moving parts.
SX™
Service and Maintenance Manual
SEALER ASSEMBLY
Right Sensor
in Machine
SECTION 3 – COMPONENT REPAIR
To replace the left stripper plate sensor,
follow steps 7 through 12:
7. Remove the film feed drive motor from the
machine. Unplug the cable, and remove the
four mounting screws (Figure 3-351).
Figure 3-351. File Feed Drive Motor Mounting
8. Remove the sensor mounting screw, identified
in Figure 3-352.
Left
Sensor
Mounting
Screw
Figure 3-352. Left Sensor Mounting Screw