RED RELAY 24V
The red 24V Relay is only present in Sharp SX
Baggers that are equipped with a printer.
relay receives an end of print signal from the printer
and communicates that to the PLC.
TESTING
WARNING
Always remove electrical power from the
SX prior to performing any maintenance
on the machine.
1. Remove the six screws holding the Frame
Cover. Set screws and Frame Cover aside
(Figure 3-110).
2. Remove fuse drawer from top of Relay (Figure
3-111).
3. With a DVOM set to test for continuity, contact
one probe to each side of the fuse. If the
DVOM does not indicate continuity, replace
fuse.
Note: A blown fuse can be an indication of a
larger issue. If you continue to blow fuses
inspect the wiring for shorts or frays.
4. Push the fuse back into position.
Note: Occasionally this fuse will not make a
good contact with the fuse holder. Reseating
the fuse may resolve the issue.
5. With a DVOM (Digital Volt/Ohm Meter) set to
test continuity, probe between pins 1 and 2 of
the relay. The DVOM should not indicate
continuity.
SX™
Service and Maintenance Manual
SECTION 3 – COMPONENT REPAIR
ELECTRICAL COMPONENTS
TM
This
3-41
Figure 3-110. Frame Cover Screws
2
1
3
4
Figure 3-111. Grey Relay location
960714-02B © 2007 I2407