Sharp SX 1075 Service Maintenance Manual page 70

Table of Contents

Advertisement

LAMINATED WHITE RIBBON CABLE
(con't)
4. Remove Cable.
5. Insert one side of the replacement cable in
Position 1 with exposed metal contacts facing
up and lock down (Figure 3-131).
6. Follow the LEFT edge of the cable (Pin 1) and
insert cable into Position 2 with that edge on
TOP.
7. Lock down the other end of cable.
8. Secure cable into position with cable ties.
9. Replace Frame Cover.
SX™
Service and Maintenance Manual
ELECTRICAL COMPONENTS (1099 & 1108)
SECTION 3 – COMPONENT REPAIR
Pin 1
Figure 3-131. White Ribbon Cable Position 1
Figure 3-132. White Ribbon Cable Position 2
3-50
Pin 1
960714-02B © 2007 I2407