12.
Set the network configuration as follows.
Navigation window  "Parameter"  "Module Information"  "RD77GF16"  "Module Parameter (Network)"  "Basic
Settings"  "Network Configuration Settings"
• RX/RY and RWw/RWr setting of the local station is for standard communications.
• RX/RY setting of the remote device station is used as a remote control and monitor input signal in standard
communications.
• RWw/RWr setting of the remote device station is used in the system of safety communications. Always set 16 points.
13.
Set the refresh settings as follows.
Navigation window  "Parameter"  "Module Information"  "RD77GF16"  "Module Parameter (Network)"  "Basic
Settings"  "Refresh Settings"
• The refresh settings are for standard communications.
14.
Log on to the programmable controller.
[Online]  [User Authentication]  [Log on to PLC]
• If logon cannot be performed, writing user information or initializing all information of the programmable controller is
required. (GX Works3 Operating Manual)
15.
Write the set parameters to the Safety CPU on the master station.
[Online]  [Write to PLC]
3 PROGRAMMING
92
3.2 Communication Example of Safety Communication Function