Mitsubishi Electric RD77GF8 User Manual page 167

Melsec iq-r series, simple motion module
Table of Contents

Advertisement

No.
Name
SW01E9
Inter-module
synchronization cycle
over count
SW01EA
Inter-module
to
synchronization cycle
SW01EB
setting value
Description
Stores the cumulative count that a link scan could not complete an Inter-module synchronization cycle.
The stored count is cleared by turning off and on the power supply or resetting the CPU module.
• 0: Cycle over not occurred
• 1 to 65535: Cumulative number of times
Stores the setting value in "Inter-module Synchronous Setting" in the [Inter-module Synchronous Setting] tab of the
"System Parameter" window. (Unit: s)
0 is stored when the inter-module synchronization function is not used.
Appendix 4 List of Link Special Register (SW)