Mitsubishi Electric RD77GF8 User Manual page 162

Melsec iq-r series, simple motion module
Table of Contents

Advertisement

No.
Name
SW00F8
Network No. match
to
status
SW00FF
SW0100
CPU moderate/major
to
error status of each
SW0107
station
SW0108
Station No. duplication
to
occurrence status
SW010F
APPX
160
Appendix 4 List of Link Special Register (SW)
Description
Stores the match status between the network No. of the master station and that of the slave station.
0: Network No. match
1: Network No. mismatch
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW00F8
16 15 14 13 12 11 10
SW00F9
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW00FA
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW00FB
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW00FC
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW00FD
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW00FE
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
SW00FF
Each No. in the table represents a station No.
 is fixed to 0.
Stores the moderate/major error or stop error occurrence status of each station.
When the target station is the master/local module, the occurrence status on the control CPU is stored.
0: No moderate/major error (stop error)
1: Moderate or serious error (stop error) occurring
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW0100
16 15 14 13 12 11 10
SW0101
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW0102
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW0103
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW0104
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW0105
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW0106
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
SW0107
Each No. in the table represents a station No.
 is fixed to 0.
(Conditions)
• This register is enabled when "Baton pass status of own station" (SB0047) is off.
• When "Baton pass status of own station" (SB0047) is turned on (error), data prior to error is held.
• This register is enabled only for normally operating stations in "Baton pass status of each station" (SW00A0 to
SW00A7).
• Reserved stations and stations higher than the maximum station No. are ignored.
Stores the station No. duplication occurrence status.
0: Station No. not duplicated
1: Station No. duplicated
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW0108
16 15 14 13 12 11 10
SW0109
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW010A
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW010B
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW010C
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW010D
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW010E
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
SW010F
Each No. in the table represents a station No.
 is fixed to 0.
9
8
7
6
5
4
3
2
120 119 118 117 116 115 114 113
9
8
7
6
5
4
3
2
120 119 118 117 116 115 114 113
9
8
7
6
5
4
3
2
120 119 118 117 116 115 114 113
1
1
1

Hide quick links: