Module Operation Mode

Set the mode of the Simple Motion module.
Item
Description
Module Operation Mode
Online
• Select this mode to connect the Simple Motion module to the network for
performing data link with other stations.
Offline
• Select this mode to disconnect the Simple Motion module from the network
for stopping data link with other stations.
The following functions are disabled when "Module Operation Mode" is set to "Offline". (Page 17
FUNCTIONS)
• Cyclic transmission
• Transient transmission
• RAS (slave station disconnection, automatic return)
• CC-Link IE Field Network synchronous communication function
• IP packet transfer function
• Safety communication function

Interlink Transmission Settings

Set link device ranges when cyclic data are transferred from a station in the own network to a station in another network.
Setting procedure
The procedure for the interlink transmission settings is shown below.
1.
Select combination of modules in the "Transfer Source Module" and "Transfer Destination Module" boxes and enter
setting values.
Setting range
• Online
• Offline
(Default: Online)