Mitsubishi Electric RD77GF8 User Manual page 155

Melsec iq-r series, simple motion module
Table of Contents

Advertisement

No.
Name
SW000B
RIRD/RIWT instruction
resend count
SW0010
Reserved station
to
function disable/
SW0017
temporary error invalid
station setting
SW001A
REMFR/REMTO
instruction resend count
SW001B
REMFR/REMTO
instruction response wait
timer time
SW0030
Link dedicated
instructions processing
result CH1
SW0031
Link dedicated
instructions processing
result CH2
SW0040
Network No.
SW0042
Station No.
SW0043
Mode status of own
station
SW0046
Module type
Description
Specify the number of times the instruction is to be resent when it is not completed within the monitoring time specified
in "RIRD/RIWT instruction arrival monitoring time" (SW0009).
0: Not resent (default)
1 to 7: 1 to 7 times
If a value other than the above is specified, 7 times will be applied.
Specify the slave station for which the reserved station setting is to be temporary canceled/restored, or the temporary
error invalid station setting is to be set/canceled.
0: Not specified
1: Specified
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW0010
16 15 14 13 12 11 10
SW0011
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW0012
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW0013
SW0014
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW0015
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW0016
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
SW0017
Each No. in the table represents a station No.
(Conditions)
• For some stations, reserved station setting cannot be temporarily canceled/restored or temporary error invalid
station setting cannot be set/canceled. (Page 119 Reserved Station Function Enable, Page 121 Enable/Disable
Ignore Station Errors)
• When the submaster station No. is specified, the setting is ignored.
• Stations higher than the maximum station No. are ignored.
Set the number of resends for the REMFR/REMTO instruction.
0: Not resent (default)
Other than the above: Number of times that is set
(Conditions)
• This register is enabled when "Baton pass status of own station" (SB0047) is off.
• When "Baton pass status of own station" (SB0047) is turned on (error), data prior to error is held.
Set the response wait time for the REMFR/REMTO instruction.
0: 10 seconds (default)
Other than the above: Number of seconds that is set
(Conditions)
• This register is enabled when "Baton pass status of own station" (SB0047) is off.
• When "Baton pass status of own station" (SB0047) is turned on (error), data prior to error is held.
Stores the processing results of the link dedicated instruction that used channel 1 of the own station.
0: Completed normally
1 or greater: Completed with an error (Error code is stored.)
Stores the processing results of the link dedicated instruction that used channel 2 of the own station.
0: Completed normally
1 or greater: Completed with an error (Error code is stored.)
Stores the network No. of the own station.
Range: 1 to 239
Stores the station No. of the own station.
Range: 1 to 120, 125 (master station), 255 (station No. not set)
Stores the module operation mode setting or communication mode of the own station.
0: Online mode, normal
1: Online mode, high speed
2: Offline mode
Stores the hardware status of the own station.
b15
SW0046 0
Model type
00: Module
01: Board
10: HMI
9
8
7
6
5
120 119 118 117 116 115 114 113
to
b2 b1 b0
to
0
Appendix 4 List of Link Special Register (SW)
4
3
2
1
APPX
153
A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd77gf4Rd77gf16Rd77gf32

Table of Contents