Mitsubishi Electric RD77GF8 User Manual page 73

Melsec iq-r series, simple motion module
Table of Contents

Advertisement

Setting items
Item
Description
Device Assignment
Right-click in the setting window and select a link device assignment method from
Method
the "Device Assignment Method" menu.
• Start/End: Enter the start and end Nos. of link devices.
• Points/Start: Enter the points and start Nos. of link devices.
Link Side
Set the link refresh ranges of SB and SW. One range can be set for each SB and
SW. (Page 21 Link refresh)
Ex.
CPU Side
0000H
Device
name
(SB)
01FFH
0000H
Device
name
(SW)
01FFH
Simple Motion module
Setting range
• Start/End
• Points/Start
(Default: Start/End)
Device Name
• SB (fixed)
• SW (fixed)
Points
• SB (fixed): 16 to 512
• SW (fixed): 1 to 512
(Default: 512)
Start
• SB (fixed): 0H to 1F0H (set in increments of
16 points)
0000H
Device
• SW (fixed): 0H to 1FFH (set in increments
name
of 1 point)
(SB)
01FFH
(Default: 0H)
End
0000H
Device
• SB (fixed): FH to 1FFH (set in increments of
name
(SW)
16 points)
01FFH
• SW (fixed): 0H to 1FFH (set in increments
of 1 point)
(Default: 1FFH)
Target
• Module Label
• Specify Device
CPU module
(Default: Module Label)
Device Name
• Module label: 
• Specify Device (when link side is SB): SB,
M, L, B, D, R, ZR, RD
• Specify Device (when link side is SW): SW,
M, L, B, D, R, ZR, RD
(Default: Blank)
Points, Start, End
• Range of the device in the CPU module
• Set bit devices in increments of 16 points
and word devices in increments of 4 points.
(Default: Blank)
2 PARAMETER SETTINGS
2
71
2.3 Basic Settings