Mitsubishi Electric RD77GF8 User Manual page 85

Melsec iq-r series, simple motion module
Table of Contents

Advertisement

Item
Configured Module
Model Name
Communication
Destination
Open System
Sending Interval Monitoring Time [ms]
Safety Refresh Monitoring Time [ms]
Safety Data Transfer
Receive Data Storage
Device Setting
Device
Send Data Storage
Device
[Output to File (for Setting Confirmation)] button
*1 Set the safety connection No. starting with 1.
Even if the safety connection is set in a random line, the unset line is deleted and the No. is set starting with 1 when the [OK] button is
clicked.
Description
When the own station is the master station, the module model
name of the communication destination selected in "Select the
target module for the Safety Communication Setting" window is
displayed. (Only slave station other than the local station)
In the following cases, set the Safety CPU model name of the
communication destination.
• When the own station is a master station: When the
communication destination is a local station and the open
system of the own station is Active
Set the open system of the own station.
• Active: Safety connections are established from the own
station.
• Passive: Safety connections are established from the
communication destination.
In each safety connection, set sending interval monitoring time
for a receiving station to detect safety communication errors.
In each safety connection, set safety refresh monitoring time for
a receiving station to detect safety communication errors.
Set this item for the Active side of the safety stations that
perform safety communications.
Set a safety device of the Safety CPU where safety data are
stored.
Set a safety device of the Safety CPU where safety data are
sent.
Outputs the contents of the safety communication setting to a
CSV file.
The file is used to check whether there is no discrepancy
between the safety communication setting written to the Safety
CPU and that of the project. (GX Works3 Operating
Manual)
Setting range
• R08SFCPU
• R16SFCPU
• R32SFCPU
• R120SFCPU
(Default: Blank)
• Active
• Passive
(Default: Blank)
3.0 to 1000.0
(Default: Blank)
4.0 to 2000.0
(Default: Blank)
Device Name
• SA\X
• SA\M
• SA\B
• SA\D
• SA\W
(Default: Blank)
Points
• Bit device: 16 to 128 (set in
increments of 16 points)
• Word device: 1 to 8 (set in
increments of 1 point)
(Default: Blank)
Start/End
Range of a safety device in the Safety
CPU
(Default: Blank)
Device Name
• SA\Y
• SA\M
• SA\B
• SA\D
• SA\W
(Default: Blank)
Points
• Bit device: 16 to 128 (set in
increments of 16 points)
• Word device: 1 to 8 (set in
increments of 1 point)
(Default: Blank)
Start/End
Range of a safety device in the Safety
CPU
(Default: Blank)
2 PARAMETER SETTINGS
2.4 Application Settings
2
83