Symmetricom TimeProvider 5000 User Manual page 192

Ieee 1588 grand master clock / ntp server
Hide thumbs Also See for TimeProvider 5000:
Table of Contents

Advertisement

Chapter 3
TimeProvider 5000 CLI Command Set
Examples 1:
To display Acceptable Master info for the Port 1 client at IP address
192.168.106.99, VLAN ID 4094 
tp5000> show ptp-node acc-master ioc-1 address
Response 1:
Acceptable table from:
ptp client ip address
ptp client vlan id
ptp client clock id
The detailed acceptable master table:
Master1 protocol type
Master1 ip address
Master1 priority1
Master2 protocol type
Master2 ip address
Master2 priority1
Examples 2:
To display the clock description info for the Port 1 client at IP address
192.168.106.99, VLAN ID 4094 
tp5000> show ptp-node clock-description ioc-1 address
Response 2:
Clock description report from:
ptp client ip address
ptp client vlan id
ptp client clock id
The detailed clock description:
Clock type
Physical layer protocol
Physical address
Protocol address
Manufacture identifier
192 TimeProvider 5000 User's Guide
= the VLAN on the Grandmaster Ethernet port
vlan-id
connecting to the client .
192.168.106.99 vlan-id 4094
192.168.106.99 vlan-id 4094
: 192.168.106.99
: 4094
: 00:b0:ae:ff:ff:01:22:99
: IPv4
: 192.168.106.14
: 0
: IPv4
: 192.168.2.11
: 0
: 192.168.106.99
: 4094
: 00:b0:ae:ff:ff:01:22:99
: Ordinary clock
: IEEE 802.3
: 00:b0:ae:01:22:99
: 192.168.106.99
: ac:de:48
098-00028-003 Revision A – June, 2011