Setting an E1/T1 Input as Reference

An E1 or T1 input can be configured as a frequency reference. For details about
configuring the E1 or T1 input parameters, see
E1/T1
Inputs, on page 265.
Example
To provision I/O ports 1 and 2 as inputs and use either as the reference, perform the
following steps:
1. Login at the Admin or Config-user level (see
2. Type
set ref mode frequency
Note: Command "set ref mode time" has the same meaning as
"set tod-source GPS" and the command "set ref mode
frequency" has the same meaning as "set tod-source sys".
The
3. Type
set ref criteria priority
Note: SSM and MANUAL are supported in v1.2 release. However the
v1.3 release only supports PRIORITY for reference selection, so
SSM and MANUAL should not be used.
SSM will be supported in v2.0 release.
4. Type
set io port1 input
5. Type
set io port2 input
6. Type
set input state port1 enable
7. Type
set input state port2 enable
8. Type
show ref
to Frequency..
Note: Disabling the input port will clear all alarms and events related
to this port.
098-00028-003 Revision A – June, 2011
and press Enter.
set tod-source
command has been deprecated.
and press Enter.
and press Enter.
and press Enter to verify that the reference mode has been set
Provisioning the Input Reference
Provisioning the Programmable
Logging
In, on page 235).
and press Enter.
and press Enter.
and press Enter.
TimeProvider 5000 User's Guide 301
Chapter 4 Provisioning