17
SET MODE
DV Set mode (Continued)
DV Auto Detect
DV Set > DV Auto Detect (DV Auto Detect)
Turn the DV mode automatic detect function ON or
OFF.
If you receive a non-digital signal during DV mode op-
eration, this function automatically switches to the FM
mode.
• OFF: Turns the function OFF. The operating mode is
fi xed to the DV mode.
• ON: Automatically selects the FM mode for tempo-
rary operation.
RX Record (RPT)
DV Set > RX Record (RPT) (RX Record (RPT))
The transceiver can record the data of up to 50 indi-
vidual calls.
When the received signal includes a status message
("UR?" or "RPT?") that is sent back from the access
repeater, you can record up to 50 messages or only the
latest one, in the Received Call Record.
• ALL:
Records up to 50 calls.
• Latest Only: Records only the latest call.
BK
DV Set > BK (BK)
The BK (Break-in) function allows you to break into a
conversation, where the two other stations are commu-
nicating with call sign squelch enabled.
• OFF: Turns the function OFF.
• ON: Turns the function ON.
"BK" appears on the display.
NOTE: The BK function is automatically turned OFF
when transceiver is turned OFF.
EMR
(Default: OFF)
DV Set > EMR (EMR)
The EMR (Enhanced Monitor Request) communica-
tion mode can be used in the digital mode. In the EMR
mode, no call sign setting is necessary.
When an EMR mode signal is received, the audio
(voice) will be heard at the specifi ed level even if the
volume setting level is set to minimum level, or digital
call sign/digital code squelch is in use.
• OFF: Turns the function OFF.
• ON: Turns the function ON.
NOTE: The EMR function is automatically turned
(Default: ALL)
OFF when transceiver is turned OFF.
EMR AF Level
DV Set > EMR AF Level (EMR AF Level)
Set the audio output level to between 0% (no audio),
1% (minimum) and 100% (maximum) for when an EMR
communication mode signal is received.
When an EMR signal is received, the audio will be
heard at the set level, or the [AF] control level, which-
ever is higher.
To disable the setting, set it to "0%."
(Default: OFF)
NOTE: After an EMR signal disappears, the audio
level will remain at the EMR level. In this case, rotate
[AF] to adjust the audio level.
17-14
"EMR" appears on the display.
(Default: OFF)
(Default: 50%)