Event message
NTP: Time synchronisation
re-established
Outgoing call rejected
Overheat
(Mitel 415/430
only)
Overheat
(Mitel 470 only)
Overload detected on USB
port (CPU2)
(Mitel 470 only)
Port out of service
Mitel 470 as of R4.1
syd-0585/1.2 – R4.1 – 08.2016
Trigger condition
Time synchronization via the NTP server (NTP =
Network Time Protocol) has been restored.
Call rejected by the network
• On any line: error code 34
• On required line group:
error code 44
The temperature inside the communication
server is too high. The appropriate measures
must be taken immediately to improve the heat
dissipation, e.g. by providing the required clear-
ances, lowering the ambient temperature or
installing the fan from the rack-mounting set
(Mitel 430 only).
The temperature inside the communication
server is too high. Appropriate measures must
be taken immediately to improve heat dissipa-
tion. Measures are automatically adopted,
depending on where the overheating occurs:
FXO and FXS interface card:
• the ports are deactivated in groups of 4 ports.
• Once they have cooled down below a defined
card-specific value, the ports are automatically
reactivated group by group.
CPU2 applications card
• The card will be completely deactivated. Once
it has cooled down below a defined value, the
card is automatically reactivated.
Internal power supply unit PSU2U or call man-
ager card CPU1:
• the communication server will be shut down
completely.
Notes:
• To prevent the system from overheating, no
more than 30% of the FXS ports should be
active simultaneously per 32FXS card and no
more than 50 FXS ports per system.
• PRI, BRI and DSI cards do not have tempera-
ture sensors and are therefore never deacti-
vated due to overheating.
A (current) overload was detected on one of the
USB interfaces on the applications card (CPU2).
Note: The maximum current input at the USB
interfaces varies:
(see also Tab. 29)
A port previously in operation has stopped func-
tioning.
Operation and Maintenance
1)
Details
Date, time
Port number of the
exchange line circuit,
cause, date, time
Card number, tem-
perature, date, time
Card number, tem-
perature, date, time
Date, time
Number of the slot,
relevant port number,
date, time
Severity
Serious
(positive,
with
match)
Normal
(without
match)
critical
(negative,
with
match)
critical
(negative,
with
match)
Normal
(without
match)
Normal
(without
match)
231