Ambient conditions
Condition
Ambient temperature
Relative air humidity
Tab. 116
Electrical data
Class of protection
Input voltage
Input current
Resistant to voltage breaks
Power input with min. configuration
Power input with max. configuration
Undervoltage limit
(system reset, data backup)
Tab. 117
Heat dissipation
Basic system with auxiliary power supply unit
Maximally configured system
7. 4. 4

Dimensions of cards and modules

Tab. 118
Dimensions of cards and fan-out panels
Card
Interface cards
Call Manager card CPU1
Applications card CPU2
Fan-out panel FOP
258
Mitel 470
no isolation
no isolation
no isolation
Mitel 470
5 °C to 45 °C
30 % to 80 %, non-condensating
Internal power supply
Mitel 470
1
103 V...127 V or 207 V...253 V,
48...62 Hz
approx. 0.2 A...2.2 A (with 115 V)
approx. 0.1 A...1.1 A (with 230 V)
< 20ms
approx. 25 W
approx. 140 W
< 90 V
approx. 140 W = 504 kJ/h
approx. 400 W = 1440 kJ/h
Dimensions width x height x depth [mm]
93 x 41 x 265
154 x 41 x 265
154 x 41 x 265
481 x 44 x 69
Auxiliary power supply unit
(APS2)
100 V...240 V, 48...62 Hz
approx. 0.2 A...4.0 A (with
115 V)
approx. 0.2 A...2.0 A (with
230 V)
< 20ms
approx. 25 W
approx. 260 W
< 90 V
Mitel 470
Mitel 470 as of R4.1
syd-0585/1.2 – R4.1 – 08.2016