Installation
Tab. 83
Connections on the Mitel DECT radio units
RJ12 sockets Pin
1
2
3
4
5
6
If an SB-8 / SB-8ANT is operated on two DSI interfaces, it is recommended always to
use two neighbouring ports.
Mitel Advanced Intelligent Network:
As the DECT systems of the individual nodes in an AIN do not run synchronously, the two DSI
interfaces of an SB-8 / SB-8ANT must always be connected to the same node.
Tab. 84
Operating state display on Mitel DECT radio units
LED flashing (two LEDs on the SB-8)
green
red / green
orange
red
not flashing and not lit
For further display variants, see "Operating state of the Mitel DECT radio units",
page 246
4. 8. 8
Analogue phones Mitel 6710 Analogue, Mitel 6730
Analogue
The phones can be used as desktop model or as wall model.
Connecting the phone
1. Stick the connector on the longer, straight end of the handset cord on the underside
of the phone into the socket with the handset symbol until it snaps into place. Feed
the cable through the strain relief and connect the other end to the handset.
2. Feed the small connector of the phone connection cable on the rear side of the
phone into the socket until it snaps into place. Stick the connector on the other end
into the phone cord.
172
Socket 1: DSI interface
SB-4+
Local power supply –
b1
a1
Local power supply +
Information
Operating state
Startup procedure running
Transmission of DECT sequences
Fault
LED switched off or radio unit defective or not in operation
SB-8 / SB-8ANT
Local power supply –
b2
b1
a1
a2
Local power supply +
Socket 2: Power supply
SB-4+ / SB-8 / SB-8ANT
Local power supply –
Local power supply +
Mitel 470 as of R4.1
syd-0585/1.2 – R4.1 – 08.2016