Installation
Fig. 35
Connection possibilities for BRI network interfaces
Notes
– The interfaces of sockets 1 to 4 can be switched to BRI-S. The interfaces of sockets 5 to 8
are permanently configured to BRI-T.
– Circuit type as per EN/IEC 60950: SELV
The connection from the front panel to the NT1 (Network Termination) is via standard
commercial straight patch cables with 8-pin RJ45 connectors on both sides. With the
appropriate tools you can also create your own cables.
Cable Requirements
Tab. 45
Cable requirements for basic rate interface BRI-T
Core pairs × cores
Stranded
Wire diameter, core
Screening
Characteristic impedance
Wave attenuation
Near/crosstalk attenuation
BRI basic rate interface network-side
Exchange
[1]
Do not connect power supply NT1
[2]
Do not fit the jumper
Fig. 36
Basic access on NT1
118
1 × 4 o 2 × 2
yes
0.4...0.6 mm
recommended
< 125 Ω (100 kHz), < 115 Ω (1 MHz)
< 6 dB/km (100 kHz), < 26 dB/km (1 MHz)
> 54 dB/100 m (1 kHz to 1 MHz)
Mains power
[1]
NT1
BRI-T
U
c
a
d
b
e
f
[2]
Communica-
tion server
BRI-T
c
d
e
f
Mitel 470 as of R4.1
syd-0585/1.2 – R4.1 – 08.2016