Connecting The Cable Screening - Mitel 470 System Manual

Version r4.1; mivoice office 400 series, aastra 470
Hide thumbs Also See for 470:
Table of Contents

Advertisement

Direct connection
Socket-outlet
Mains power
Protective wire
Building earth
Fig. 22
Earthing of the communication server in the case of direct cabling and indirect cabling
Note
In the case of an indirection connection make sure that the communication server's earthing
wire does not form any earth loops with the earthed cable screenings of the installation cables
leading up to the (main) distribution frame. The cables should be kept as short as possible and
laid out in parallel.
4. 3. 2

Connecting the cable screening

When using shielded installation cables also use shielded RJ45 connectors. In this
way the shielding of the installation cables is automatically connected with the housing
of the communication server and therefore with the building earth.
Note
Connect the cable screens to one another at the splitting point only. Observe the tree structure
principle to prevent earth loops.
Mitel 470 as of R4.1
syd-0585/1.2 – R4.1 – 08.2016
Mitel 470
Copper wire yellow/
green 2,5 mm
2
protected 4,0 mm
2
unprotected
Indirect connection
Mains power
Protective wire
(Main) distribu-
tion board
Copper wire yellow/ green
2,5 mm
Building earth
unprotected
Installation
Socket-outlet
Mitel 470
2
2
protected 4,0 mm
101